Device Management

Manage a digital twin, replace its physical sensor, reconnect measurements, and review retained history in Kilo IoT Server.

A digital device is the lasting record of the asset or monitoring point you manage. Its physical source can change while the twin keeps its name, measurements, and stored history. Open the device to update its details, replace hardware, check incoming readings, or review history. For the full concept and refrigeration example, see Devices.

Opening a device's detail page

There are several ways to open the detail page for an existing device:

  • From Devices — Click any device row in the Devices list in the sidebar. The device detail page opens showing that device's current state.

  • From a connector — Open its connected-device list and select the existing device. + Add device starts a new registration; it is not the replacement workflow.

  • Edit button — Click the edit icon (pencil) on any device row to go directly to the device detail page.

Replace a physical sensor

Use this procedure when the monitored asset stays the same but its hardware needs replacing. For example, keep Refrigerator 1 when replacing a temperature probe that has failed or no longer meets your calibration requirements.

You need permission to edit devices, the replacement hardware's identifiers and connection settings, and access to the connector it will use. Record the existing measurement names, units, connector keys, and the time of the change. Arrange any necessary monitoring coverage during the replacement: the platform cannot record measurements that no device sends.

  1. Open Devices and select the existing digital device, such as Refrigerator 1.

  2. Check its measurement rows and recent Logs. Keep the temperature measurement that already contains the refrigerator's history.

  3. Open Connection. For a bound LoRaWAN probe, click the X control labeled Detach physical device beside Device EUI. Detaching takes effect immediately; it is not deferred until the next Save. The digital device and its measurement channels remain, while the old physical binding and source mappings are removed.

  4. Enter the replacement's Device EUI, AppKey, and matching device profile. Check its decoder and Data sending interval, then click Save. For another supported source type, use that connector's identifier and configuration fields.

  5. Open Mapping. For each existing measurement, select the replacement's incoming Connector key and click Save. For example, change the source of the existing temperature measurement from temp_c to temperature. Check that the new value is in the same unit and format.

  6. Wait for a new transmission. Confirm that Value and Last update change, and use the Connection diagnostics if they do not.

  7. In Logs, choose a date range spanning the change. Check readings from before and after replacement, then check the dashboard and any rules using those measurements.

Keep the existing measurement rows. Change their connector keys instead of removing the rows and creating new ones. Stored history and dashboard/rule references belong to those measurements; reusing a name is not the same as retaining the original measurement.

Detaching hardware is also different from deleting the digital device. If a replacement fails to connect, keep the twin and use Device Diagnostics to check reception and mapping. Earlier readings remain subject to your retention period.

For an emulator-to-hardware change, use the dedicated go-live workflow, which changes the source without first detaching it.

Swap between an emulator and hardware

Swap connection is available when there is an eligible connection involving the emulator: emulator to real hardware, or real hardware to emulator. It is not a physical-to-physical replacement control.

  1. Open Connection and click Swap connection. The connection picker shows eligible destinations and unlocks the target identity fields.

  2. Choose the destination, fill its required configuration, and review mappings and commands for the new source.

  3. Click Save to apply the swap. Cancel swap exits swap editing before saving and restores the original connection fields.

  4. Confirm the new source supplies the expected readings. Keep the retained measurement identities; generated readings and real readings both remain subject to the history retention period.

For one physical sensor replacing another, use Detach physical device, bind the replacement and restore its key mappings. Detach takes effect immediately; it does not wait for the page's Save button. It removes the physical binding and source mappings while retaining the twin and its measurement channels.

Device info tab

The Device info tab contains the device's identity and visual reference:

  • Device photos — Upload, replace, or remove photos of the asset or its hardware. A refrigerator photo can remain useful after its probe is replaced.

  • Device name — Update the display name at any time. A consistent naming convention (e.g., including location or device type) helps when managing large fleets.

  • Application — Choose the solution this device belongs to, or Default for no named application.

Photo controls: Use Add photo or drag PNG/JPG files onto the upload area. You can keep up to three photos; the UI recommends 5 MB per photo. The first photo is the cover. Use the remove control on a photo to remove it from the edited list, then save. The name is required; Application assigns the twin to a named setup, or Default leaves it outside a named application. Save profile changes before leaving the page.

Connection tab

The Connection tab manages the twin's current data source. The source's hardware identifier belongs here; the asset's lasting name belongs in Device info. The available fields depend on the connector type.

Connector selection

The Connector type dropdown shows available connectors in your organization. A link below the dropdown directs you to the Connectors section if you need to add a new connector.

Changing the connector re-binds the device to a different data source, and is offered only for pairs that involve the Emulator — emulator to real, or real back to emulator. To replace one physical source with another, detach the old source and bind the replacement to this twin. See Emulated Devices.

For LoRaWAN devices (LNS connector)

Follow LoRaWAN Devices for every identity, profile, codec and reporting-interval field. Existing physical identifiers are locked; detach before replacing hardware. Keep the same digital device and measurement rows, then restore the source-key mappings.

For vehicle trackers (Tracker connector)

  • Unique ID — The tracker's device identifier. Locked once bound.

  • Device model — Search and select from the tracker model library.

  • Url for GPS tracker — The endpoint URL displayed after selecting a model. Copy this URL and configure the physical tracker to send data to it.

Mapping tab

The Mapping tab connects incoming data keys to retained measurement channels. Use the same measurement rows when a sensor is replaced: changing an incoming key is different from replacing the measurement itself.

Column or control
Purpose and configuration

Device data key

Select a received source field, such as temperature or vibration.rms. This is the incoming connector key. Options appear after messages arrive; a blank choice records nothing for this measurement. Save changes to this key with Save.

Value

Latest received value for the selected source key. This snapshot is not the historical record.

Last update

When that source key was last received. An empty value means no corresponding received value is available.

Normalized key

Choose the metric template defining the measurement. Only Telemetry templates are offered. A template already assigned to this device is disabled in the dropdown.

Unit

The template's unit, shown for reference. Set or change it in metric templates; the mapping does not perform unit conversion.

Type

Read-only template value type: Integer, Float, String or Boolean. It controls conversion of incoming readings.

Data type

Telemetry in this mapping form. Reported switch states can be recorded as telemetry too.

Add key

Add a mapping row, then select a template and an incoming key.

+ Add new metric

Opens Add Metric from the Normalized key dropdown. Enter a non-empty Normalized key, choose Type (initially String), and keep Data type as Telemetry. Add creates the template and selects it; Cancel closes without creating it. This compact dialog has no unit selector; use the full metric catalog to configure units.

Remove

Removes the row and its measurement assignment immediately on a saved device. This is not the procedure for changing hardware.

Selecting a template adds its measurement immediately on an existing device. Selecting a different template on an existing row removes the old measurement assignment and creates the new one. Closing the page without clicking Save does not undo those actions. Preserve templates during replacement and change only source-key assignments, then save.

After saving mappings, allow a fresh message and check Logs. A field can appear in the incoming snapshot before its mapping is complete; older messages are not backfilled. Match template types to the actual values: "ON" and "OFF" are strings, while true and false are booleans. See metric templates for conversion and rejection rules.

Asset identification

Use the device name, photo, and application assignment to identify the monitored asset. Keep calibration certificates, installation notes, and maintenance records in your organization's record-keeping system; device measurement history is not a maintenance log.

Commands & States tab

For devices that can receive downlinks — MQTT devices, LoRaWAN devices, and emulated devices with Support commands enabled — a Commands & States tab appears. This is where you define the actions a device can perform and dispatch them on demand, turning the Digital Twin from a read-only record into a control surface. The full workflow has its own section: see Device Commands.

Logs tab

The Logs tab displays stored readings for the digital device's attached measurements, within the available retention period. It can therefore show readings from an earlier physical source as well as its replacement when you keep those measurements. A status indicator in the device header reflects its live connection and logging activity, so you can tell at a glance whether new data is currently flowing in.

Log entries are grouped by the minute. All readings received within the same minute are collected under a single group header — so even when several batches arrive in the same minute, the view stays tidy. Click a group header to expand or collapse the readings inside it. Each entry within a group shows:

Column
Description

Key

The measurement's normalized key

Type

The data type of the value

Value

The received value

Date filtering: Click the date button in the top-right corner of the Logs section to open a date range picker. You can select a preset range (e.g., "Last week") or define a custom date range to narrow the log view. This is especially useful for investigating specific incidents or reviewing data from a particular time window.

The Logs tab shows you the readings themselves. If the readings are missing and you need to know why — whether messages reached the platform at all, whether their keys matched your sensors, and whether the values were stored — read the reception status, pipeline, and event feed on the Connection tab. See Device Diagnostics.

The date button shows the current preset or date range. Choose a quick range or a custom start/end range and click Apply changes. Clear filter resets the selection. Available dates and presets are limited by your plan's retention. Timestamp identifies each reading; Key is the normalized measurement name, followed by Type and Value. Expand/collapse the minute groups to inspect individual readings. No logs found means no retained readings match the range; check mapping and a fresh message before widening it. If loading fails, reload the page.

Copying a device

Click the copy icon on a device row to create a new device pre-filled from that one. The form arrives carrying the original's name, its metric-template rows, its connection selection and settings, and its images. Identity is deliberately not carried: give the copy its own name and its own device identifier before saving.

For a physical device, the copy creates new measurement rows from the selected templates. Open the saved copy and assign its Connector keys; pre-filled source mappings are not saved onto the new measurement identities.

An emulator copy also carries its generated signal configuration, reporting interval, command-support setting, and preset commands. Give it a new Device ID before saving. See Copying an emulated device.

Copying creates another digital device with its own measurements and history. It does not transfer historical readings. Use the original twin when replacing hardware on the same asset.

Common management tasks

Task
Where
How

Rename a device

Device info tab

Edit the Device name field and save

Re-bind to a different physical device

Connection tab

Detach the current physical device, enter new identifiers, then reconnect existing measurements

Change from manual to template profile

Connection tab

Check "Use device profile templates" and select Brand/Model/Profile

Add a new measurement type

Mapping tab

Add a row, select a metric template, map the connector key

Investigate missing data

Logs tab

Filter to the expected time range and review the entries

Copy a device configuration

Device list

Click the copy icon on a device row to create a new device with the same settings

Delete a device

Device list

Click the delete icon on a device row and confirm

For metric template setup, see Metrics. Use an asset-oriented name and application assignment to keep related devices recognizable.

Organize the device in an application

On Device Info, use Application to associate this device with an operational solution. Choose Default to leave it outside named applications, then save. The device can belong to one application at a time. See Organizing Content.

Protocol setup references

Use LoRaWAN Devices or MQTT Devices for the complete connection fields, then return here for common profile, mapping and history controls.