Base Station Monitoring
Track MIOTY base station status and last seen in Kilo IoT, set coordinates, regenerate certificates, delete.
Once MIOTY base stations are deployed, the Mioty Base Stations tab on the Gateways page gives you a fleet view of the radio infrastructure, and each station's detail page gives you its operational state and configuration.
The base station list
Click Gateways in the left sidebar and open the Mioty Base Stations tab.

Table columns
Name
The station name you assigned during registration
BS EUI
The station's 16-character hexadecimal identifier
Status
Current connectivity — online or offline
BSSCI URL
The service center endpoint this station holds its session to
Last seen
When the station last communicated
Before your first station is registered, the tab shows "No base stations yet".
Status and last seen read together. Status tells you the session state right now; last seen tells you how long a problem has been running. A station that went offline four minutes ago during a scheduled reboot and one that went offline nine days ago are the same status and very different incidents.
Base station detail page
Click any row to open that station's detail page. It has two tabs: Overview and Settings.
Overview tab
The Overview tab is the operational read on a single station:
Status — an online/offline indicator showing the current state of the station's BSSCI session.
Description — the notes you captured at registration: mounting details, antenna type, work order.
BSSCI URL — the service center endpoint for this station. A copy control puts it on the clipboard, with a toast to confirm.
Creation date — when the station was registered.
Last seen — the most recent communication from the station.
Map — once coordinates are set, the station appears as a marker in its real position.
Settings tab
The Settings tab is where you change what the station is and how it authenticates.
Editable fields:
Name — the station's display name across the fleet view.
Description — free-text detail.
Coordinates — latitude, longitude, and altitude. Altitude is worth entering accurately on multi-story or mast installations; a station on a 40 m stack and one at grade cover very different footprints from the same map pin.
Click Save changes. A toast confirms "Base station updated". If the change cannot be applied, the toast reads "Failed to update base station" — the station's stored configuration is unchanged, so correct the input and save again.
Read-only identity: the Base station EUI is fixed after registration. It has a copy control, with a toast on copy, as does the BSSCI address.
Regenerate certificate — issues a fresh certs.zip for this station and downloads it. A card remains on the page so you can download the bundle again without repeating the operation. The station must be reconfigured with the new certificate pair; until it is, it cannot re-establish its BSSCI session.
Delete base station — removes the station from your organization. You are returned to the gateways list, and a toast confirms "Base station deleted". If the operation fails, the toast reads "Failed to delete base station" and the station remains.
Operational tips
Set coordinates at commissioning, not later. The map is the fastest way to answer "which station covers this endpoint" during an incident, and it only works if the pins are real. A fleet of stations at 0,0 is a list with extra steps.
Treat regeneration as a planned outage. Regenerating a certificate does not take the station down by itself, but it does mean the station must be reconfigured before it can reconnect after its next session drop. Schedule it with a technician who can install the new bundle, rather than issuing it and walking away.
Regenerate after physical exposure. If a station has been accessed by unauthorized personnel, or its
certs.ziphas been handled outside your controls, issue a new pair. The old certificates are what an attacker would present.Watch last seen across the fleet, not per station. Several stations going quiet in the same window is rarely a radio problem — look at the site's backhaul or power before you look at the hardware.
Delete only when the hardware is retired. A deleted station's endpoints lose the path they were attaching through. If you are relocating a station rather than decommissioning it, update its name and coordinates instead.
Last updated